Cleanroom Equipments

Bio Safety Cabinets-Type –I (100% Exhaust)

Purpose: To keep the “parts” and work in ISO ‘5’ environment so as to protect the components and process from contamination

Description: The Bio - Containment work station is a Laminar Flow Equipment / Instrument with 1 Piece tempered glass door with imported gloves & glove ports placed on gas spring, so as to avoid Spillage of Product into the Room. This Booth is provided with the centrifugal motor blower Assembly with single phase power connection to produce the required air quantity at required pressure. Fresh air is drawn from the room trough 5 micron filter, then it passes through 0.3 micron filter, and it’s way to working area, where the production is being done. And this air is exhausted through a 0.3 micron filter with the help of an exhaust motor, blower assembly. The unit is equipped with Full toughened glass / Poly Carbonate Sheet doors in working area for maintenance purpose.


Bio Safety Cabinets-Type –II (30% Exhaust)

Purpose: To keep the “parts” and work in ISO ‘5’ environment so as to protect the components and process from contamination

Description: The Bio – Hazard Safety Cabinet is a Laminar Flow Equipment. This Booth is provided with the centrifugal motor blower Assembly with Three phase power connection to produce the required air quantity at required pressure. Fresh air is drawn from the room trough 5 micron filter, then it passes through 0.3 micron filter, and it’s way to working area, where the production is being done. And this is 30% exhaust air System. This air is exhausted through a 0.3 micron filter. The unit is equipped with Full toughened glass / Poly Carbonate Sheet doors in working area for maintenance purpose


Floor Mounted Horizontal Laminar airflow work stations

Purpose: To keep the “parts” and work in ISO ‘5’ environment so as to protect the components and process from contamination.

Description: Horizontal laminar air flow Station takes fresh air from room through the 5micron Pre-filter and then passes through HEPA filter of 99.99% η before entering into the working Area, and thereby creating a clean zone conforming to class ISO ‘5’.


Floor / Table Mounted Vertical Laminar airflow work station

Purpose: To keep the “parts” and work in ISO ‘5’ environment so as to protect the components and process from contamination.

Description: Vertical laminar air flow Station takes fresh air from room through the 5micron Pre-filter and then passes through HEPA filter of 99.99% η before entering into the working Area, and there by creating a clean zone conforming to class ISO ‘5’.


Ceiling Mounted Vertical Laminar airflow work stations

Purpose: To keep the “parts” and work in ISO ‘5’ environment so as to protect the components and process from contamination.

Description: Ceiling suspended Vertical laminar air flow Station takes fresh air from room through the 5micron Pre-filter and then passes through HEPA filter of 99.99% η before entering into the working Area, and thereby creating a clean zone conforming to class ISO ‘5’.

  • Dedusting Booths
  • Personnel Air showers
  • Reverse Laminar Airflow work stations
  • Pass Through Hatch Boxes
  • Sterile Garment storage cabinets